Skip to main content

Steps

  1. Navigate to the Control Plan Risksheet — Open the Control Plan document from the Risks space or from the Control Plans Report dashboard.
  2. Locate the Control Method row — Find the level 3 row for the control method you want to configure. This row will be nested under a characteristic (level 2), which is nested under a process step (level 1).
  3. Set the Sample Size — In the “Sample Size” column, enter the number of parts to inspect per sampling event. Common values:
    • 1 for 100% inspection of critical characteristics
    • 5 for periodic sampling of stable processes
    • n=5, N=50 for acceptance sampling plans (5 samples per 50-part lot)
  4. Set the Sample Frequency — In the “Sample Frequency” column, specify when to perform inspections:
    • Every part for SC/CC special characteristics requiring 100% inspection
    • Hourly for in-process monitoring of process characteristics
    • First/last piece + 1/hr for setup validation with periodic checks
    • Per lot for batch-based inspection strategies
  5. Verify the classification drives the plan — For rows with SC (Special Characteristic) or CC (Critical Characteristic) badges, ensure sample frequency reflects the criticality. SC/CC items typically require higher frequency or 100% inspection.
  6. Consider process capability — For stable processes with high Cpk (≥1.67), reduce sample frequency. For processes still under control (Cpk 1.00-1.33), increase frequency or sample size.
  7. Align with Detection Rating — Review the PFMEA detection rating for the linked failure mode. Higher detection ratings (6-10) indicate weak controls that may require increased sample frequency to compensate.
  8. Save the control plan — Click the save button in the risksheet toolbar. Changes apply immediately to the control plan configuration.

Workflow Diagram

Decision FactorConditionRecommended Frequency
SC or CC classificationClassification = SC or CCEvery part OR First/last + hourly
Low process capabilityCpk < 1.33Increased (hourly or per shift)
High process capabilityCpk >= 1.67Reduced (daily or per lot)

Sample Frequency Patterns

Process TypeCpk RangeSC/CCRecommended FrequencySample Size
Setup/New runN/AYesFirst + Last + 1/hr5
Setup/New runN/ANoFirst + Last3
Stable process≥1.67YesEvery part OR Hourly1 OR 5
Stable process≥1.67NoPer shift5
Marginal process1.00-1.33YesEvery part1
Marginal process1.00-1.33NoHourly5
Unstable process<1.00Any100% until stable1
  • Missing frequency for SC/CC characteristics — Special characteristics require documented sampling plans. Leaving frequency blank fails IATF 16949 control plan audits.
  • Sample size without frequency — Specifying “n=5” without stating “when” makes the control plan unenforceable on the shop floor.
  • Over-inspection waste — Inspecting stable processes hourly when daily would suffice increases cost without quality benefit. Use Cpk data to justify reduced frequency.
  • Undersampling critical features — Reducing frequency on SC/CC items to save cost risks customer escapes. Always justify frequency reductions with statistical evidence.
  • Link to SPC systems — If your shop floor uses Statistical Process Control software, reference the SPC chart ID in the control method description. This connects real-time monitoring to the control plan.
  • Document MSA requirements — For variable gauging (measurement-based inspection), add a note requiring Measurement System Analysis (MSA) validation. This ensures the sample frequency is meaningful only if the measurement system is capable.
  • Use acceptance sampling standards — For lot-based inspection, reference ANSI/ASQ Z1.4 (formerly MIL-STD-105) sampling plans. Example: “AQL 1.0, Level II, General Inspection” provides unambiguous frequency and accept/reject criteria.
  • Align with PFMEA detection ratings — If detection rating is 6 or higher (low detection capability), compensate with increased sample frequency or move to 100% inspection until detection can be improved through design or automation.

Verification

You should now see the “Sample Size” and “Sample Frequency” columns populated for each control method row. Critical characteristics (SC/CC) will have orange or red row backgrounds with higher frequency or 100% inspection specified. When you navigate to the Control Plans Report, the control plan metrics will reflect the number of control methods with documented sampling strategies.